Gaggenau | Glass Downdraft Table Ventilation 200 Series

The 200 Series Gaggenau Glass Downdraft Table Ventilation, effectively and discreetly, prevents steam, heat and vapour from permeating an open-plan setting. Embedded within the counter, along the top edge of your large induction cooktop, both black appliances blend into one even as the transparent screen emerges.

The open kitchen concept, whereby the kitchen and living space become one, demands exceptional ventilation to prevent steam, heat and vapour permeating the open-plan setting. However, a large extractor doesn’t necessarily fit the design aesthetic of your entertainment space.

The table ventilation 200 series is the solution. Embedded within the counter, it is discreetly placed along the top edge of your large induction cooktop, the black appliances blending into one. Unseen until it emerges, the extractor’s discretion continues; it is utterly transparent. Clearing the air and the view of the cooktop even enlightens with ambient illumination.

Extracting, recirculating, guiding the air
The table ventilation utilises Guided Air technology; additional airflow behind the screen that captures more vapour in front of the screen. This innovation increases the air extraction, from pans anywhere on the cooktop.

Control the air
Available in 80 cm and 90 cm width options, it is flush-fitted and harmonises with our large, frameless, induction and full surface induction cooktops. Home Connect enabled, controllable via compatible cooktops, it can be set to automatically detect and remove vapour, even after cooking, allowing you to concentrate on the cuisine.

Valuable drawer space is saved and installation is simplified as only one cut-out is needed. When in re-circulation mode, we can guarantee the efficient removal of odours using activated charcoal filters. For maintenance, these and the dishwasher-safe grease filters, are easily removable from the top.

Details
  • Category
    Rangehoods
  • Brand
    Gaggenau
80CM Specifications

Output

  • Air extraction (min/max) according to EN 61591: 223 / 775 m³/h.Noise (min/max): 39 / 70 dB (A) re 1 pW.
  • Air recirculation (min/max) according to EN 61591 (with standard filters): 170 / 562 m³/h.Noise recirculation (min/max): 43 / 70 dB (A) re 1 pW.

Features

  • Cooktop-based ventilation control.
  • Automatic function with sensor-controlled run-on function.
  • 3 electronically controlled power levels and 1 intensive mode.
  • Grease filter saturation indicator.
  • Activated charcoal filter saturation indicator.
  • 2 large-scale metal grease filters included, easy to remove, dishwasher-safe.
  • Overflow capacity 170 ml in grease filter. Additional capacity 600 ml in the remote fan unit.
  • Activated charcoal filter easily removeable from above for air recirculation system.
  • Gaggenau Black anodized aluminium frame.
  • 1 user interface to set the power levels and 1 user interface to control the Guided Air technology.
  • Fan technology with highly efficient, brushless DC motor (BLDC).
  • Flexible installation of the fan unit at the front (for a compact wall solution), at the back (without loss of drawer space), or at a distance from the appliance.
  • Home network integration for digital services (Home Connect) wireless via WiFi.
  • The use of the Home Connect functionality depends on the Home Connect services, which are not available in every country. For further information please check: home-connect.com. 

Planning Notes

  • Compatible with 80cm frameless cooktops 400 series (CX 482) or 200 series (CI 282), in a single worktop cut-out.
  • For installation in a single worktop cut-out the installation accessory VA200080 must be placed between the appliances. This includes a connection strip and furniture supports that ensure cabinet stability.
  • The table ventilation can be installed in the cabinet or between two (e.g. for an island installation deeper than 100 cm).
  • No upper cabinets should be installed above the table ventilation to maintain optimum performance.
  • The following distance should be observed:- 50 cm left and right of the table ventilation to the wall or neighbouring tall cabinets.- 5 cm from the table ventilation frame to the wall.
  • Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer.
  • To install the fan unit at a distance, an installation kit AA200910 is required (with spare covers for closing air outlets). Maximum distance 3 m.
  • In air extraction, a one-way flap with a maximum opening pressure of 65 Pa should be installed.
  • In air extraction mode, always ensure adequate fresh air in the room if the appliance is being operated at the same time as a chimney-vented fireplace.
  • For optimum performance in air recirculation we recommend an outflow surface area of at least 440 cm².
  • For air recirculation, an air recirculation module (AA200880 or AA200882) is required. 

Connection

  • Total connected load 300 W.
  • Connection cable 1.3 m, detachable.
  • Power consumption standby/display off 0.4 W.
90CM Specifications

Output

  • Performance and noise output levels:Air output according to EN 61591.Sound power level according to EN 60704-3.
  • Air extraction (min/max) according to EN 61591: 229 / 833 m³/h.Noise (min/max): 41 / 71 dB (A) re 1 pW.
  • Air recirculation (min/max) according to EN 61591 (with standard filters): 172 / 620 m³/h.Noise recirculation (min/max): 43 / 71 dB (A) re 1 pW.
  • Odour reduction: > 90 %

Features

  • Cooktop-based ventilation control.
  • Automatic function with sensor-controlled run-on function.
  • 3 electronically controlled power levels and 1 intensive mode.
  • Grease filter saturation indicator.
  • Activated charcoal filter saturation indicator.
  • 2 large-scale metal grease filters included, easy to remove, dishwasher-safe.
  • Overflow capacity 170 ml in grease filter. Additional capacity 600 ml in the remote fan unit.
  • Activated charcoal filter easily removeable from above for air recirculation system.
  • Gaggenau Black anodized aluminium frame.
  • 1 user interface to set the power levels and 1 user interface to control the Guided Air technology.
  • Fan technology with highly efficient, brushless DC motor (BLDC).
  • Flexible installation of the fan unit at the front (for a compact wall solution), at the back (without loss of drawer space), or at a distance from the appliance.
  • Home network integration for digital services (Home Connect) wireless via WiFi.
  • The use of the Home Connect functionality depends on the Home Connect services, which are not available in every country. For further information please check: home-connect.com.

Planning Notes

  • Compatible with frameless cooktops 400 series (CX 492) or 200 series (CI 292), in a single worktop cut-out.
  • For installation in a single worktop cut-out the installation accessory VA200080 must be placed between the appliances. This includes a connection strip and furniture supports that ensure cabinet stability.
  • The table ventilation can be installed in the cabinet or between two (e.g. for an island installation deeper than 100 cm).
  • Width of the cabinets 90 cm, 100 cm or 120 cm.
  • No upper cabinets should be installed above the table ventilation to maintain optimum performance.
  • The following distance should be observed:- 50 cm left and right of the table ventilation to the wall or neighbouring tall cabinets.- 5 cm from the table ventilation frame to the wall.
  • Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer.
  • To install the fan unit at a distance, an installation kit AA200910 is required (with spare covers for closing air outlets). Maximum distance 3 m.
  • In air extraction a one-way flap with a maximum opening pressure of 65 Pa should be installed.
  • In air extraction mode, always ensure adequate fresh air in the room if the appliance is being operated at the same time as a chimney-vented fireplace.
  • For optimum performance in air recirculation we recommend an outflow surface area of at least 440 cm².
  • For air recirculation an air recirculation module (AA200880 or AA200882) is required.

Connection

  • Total connected load 300 W.
  • Connecting cable 1.3 m, pluggable.
  • Power consumption standby/display off 0.4 W.
Visit Website

About the
Seller

Inspiration for your place, at ours.

Looking for inspiration? You’ll find it at UnserHaus. Step inside and discover a world of creativity, food, design and technology, all under one roof. You’re invited to experience our innovative showroom concept; a place where likeminded people gather to connect, and a collection of exceptional German appliance brands is waiting. If you’re thinking about appliances, think UnserHaus.

Three German Appliance Brands in One Place. How very efficient.

BOSCH | GAGGENAU | NEFF

At ArchiPro we recognise and acknowledge the existing, original and ancient connection Aboriginal and Torres Strait Islander peoples have to the lands and waterways across the Australian continent. We pay our respects to the elders past and present. We commit to working together to build a prosperous and inclusive Australia.