Compliance for Frameless Glass Balustrades with UNEX

Written by

Unex Systems

07 June 2022

 • 

2 min read

banner
UNEX provides a range of interlinking handrail and laminate glass solutions for meeting the strict new NZBC regulations for glass balustrades.

There have been considerable changes around glass balustrades over the recent weeks. Frameless and semi-frameless glass balustrades without a top rail (as they have traditionally been installed) are no longer permitted.

What does this change mean?

The New Zealand Building Code (Acceptable Solutions B1/AS1 section) has recently adopted the revised NZ Glazing Standard NZS 4223.3:2016, effective from the 1st of June 2016. This change means any new structural glass balustrade will now need an interlinking handrail or one of the following alternative methods to comply with B1/AS1.

Some possible solutions by UNEX:

  1. Use the Spectra Semi-Frameless Glass Balustrade with Top Rail.
  2. Select a UNEX Frameless Glass System and use standard monolithic safety toughened glass in conjunction with a UNEX interlinking rail. Common examples include the AZS Side Mounted Channel with VRR Top Rail and the Metropolis AZM Top Mounted Channel.
  3. Opt for the Vetro Semi-Frameless Glass Balustrade with a UNEX interlinking rail fixed to the side of the post or glazed on top of the glass.
  4. Select a UNEX frameless glass system such as the Panorama Side Mounted Channel, Metropolis Top Mounted Channel or Arena Points; use Toughened Laminate Glass (such as EVA) and either silicon or interconnecting clamps between each pane of glass. In the event of breakage, these will hold the glass panes in place.
  5. To achieve the totally frameless look as traditionally installed, use a special glass with a stiff interlayer, such as Sentry Glass. This interlayer is designed to prevent a fall should both glass panes spontaneously break. Use in conjunction with a frameless glass system such as the AZS Side Mounted Channel, AZM Top Mounted Channel or Arena Points. Please note that the cost of this glass system is considerably more expensive than other options.

A few points to mention regarding the interlinking UNEX rail:

  • At the ends, it shall be attached to a structural building element such as to the wall or a balustrade post.
  • The rail can be either attached on the top edge of glass or using brackets off the side of the glass.
  • The interlinking rail must still meet the required serviceable barrier loads (Serviceability Limit State — SLS loads, specified in AS/NZS 1170 B1/VM1) should the pane of glass break.

At ArchiPro we recognise and acknowledge the existing, original and ancient connection Aboriginal and Torres Strait Islander peoples have to the lands and waterways across the Australian continent. We pay our respects to the elders past and present. We commit to working together to build a prosperous and inclusive Australia.