eHaus Euro - PHI Low Energy - Non Certified The first eHaus developed in 2010 as a prototype to test the theory of Passive House and the newly developed New Zealand climate data. Read more
Visit Website

Classic eHaus prototype showcasing Passive House principles, completed in 2010, featuring ecoBlock construction, modern interiors, and exceptional energy efficiency with a focus on sustainability and comfort.

eHaus Euro - PHI Low Energy - Non Certified

The first eHaus developed in 2010 as a prototype to test the theory of Passive House and the newly developed New Zealand climate data. When completed it was the most air tight house that had been built in New Zealand (0.6AC n50) and was tested by Thomas Van Ramsdonk from Proclima who had one of the few blower doors in NZ at that time. Following construction the house was monitored in 2011 – 2012.   The performance of the home met all the expectations and confirmed the decision for eHaus to focus on the Passive House Standard. A conventional external style was chosen in keeping with the subdivision but the inside is very modern. A large open plan dining, living kitchen area with en-suite that is an integral part of the master bedroom separated by a floating wall. The house was constructed using ecoBlock which proved to be an excellent option for this and many future projects.

 

Design Components

Floor: Insulated concrete pad with a U-value of 0.598 W/(m²K)

Wall: ecoBlock ICF wall  U-value = 0.267 W/(m²K)

Roof: 300mm of wool insulation U-value of 0.142 W/(m²K)

Window Joinery Frame: Thermally Broken Aluminium windows – Uf: 3.8 W/(m²K) 

Glazing: Double Glazed 4-16-4 Low E Argon U g-value = 1.3 W/(m²K)  g -value = 64 %

Ventilation: Zehnder Comfo Air 350 MHRV

Hot Water: Flat Panel Solar Hot water systems (5.4m²),  with 300 litre internal storage

Heating/Cooling: Pellet fire , 600W  Heated towel rail

Ecological features: 10,000 litres of potable water storage

 

Performance Specifications

Heating demand: 19.0 kWh/m²/yr

Heating Load: 12.0 W/m²

Frequency of Overheating: 0% year over 25°C

TFA: 188 m²

Air Leakage@50Pa: 0.6 ACH

Completed
2010
Price range
$0.5m - $1m
Building style
Classic
6581h 0m

Like this Project?
Hire eHaus

Professional Reviews

1 / 7

“You get a house with a healthy environment — there’s no condensation, no mould and no heating costs. It made sense to build this way. I like that you can control the humidity levels and the little things you notice, like the bedding is always dry. Hofmans Builders created a beautiful, high standard home, Steve and Susie and their team were great to work with and we would not hesitate in recommending them to future e-Haus clients.”